Please contact GÉANT Partner Relations for further information on available destinations partner-relations@geant.netorg.
Service Description
Availability Target
...
Service | Availability TargetAvAa |
---|---|
Unprotected Lambda (up to 1000km) | 99.5% |
SNCP Protected option | 99.995%5% |
Fully Protected (1+1) option | 99.999%5% |
Time to Restore Target
The Time to Restore (TTR) Target outlined for the three levels of service in the GÉANT Lambda offering are provided for a single fibre cut.
...
In order for an NREN to increase its GÉANT lambda capacity, please contact the GÉANT Partner Relations Team (partner-relations@geant.netorg) to discuss available options.
...
Circuit capacity | Delivery Time |
---|---|
10G10G10df10G | Up to 10 weeks |
40G | Special Special application |
100G | Up to 10 weeks |
Pricing
Lambdas are individually priced on request to ensure they are competitive with current market rates. Please contact the GÉANT Partner Relations Team partner-relations@geant.org with details of your requirements for a quotation. Please note from 2016 up to 3 (three) 10Gbps GÉANT Lambda services can be deployed free of additional charges (or 6 (six) ½ ends, if two NRENs agree to share a Lambda between them). Lambdas are only available between GÉANT PoPs. For further information please see the following Cost Sharing and subscription explanation;
Availability
Location | Address |
---|---|
Amsterdam | VANCIS B.V. RmS145 1st Floor Science Park 121 Amsterdam 1098 XG -Netherlands |
Bratislava | SITEL PoP2 Sitel Kopcianska ul. 20c Bratislava 85101- Slovakia |
Brussels | Level 3 Avenue Leon Grosjean 2 Evere - Brussels 1140 - Belgium |
Budapest | NIIF NIIF Institute 18-22 Victor Hugo Street Grn Floor NIFF Computer Rm Budapest 1132 - Hungary |
Frankfurt | InterXion Weismüllerstrasse 21-23 BUILDING FRA3 1st Floor Rm 2-1C Frankfurt 60314 - Germany |
Geneva | CERN IT-CS Building 513 385 route de Meyrin Geneva 23 1211 - Switzerland |
Ljubljana | ARNES Jamova 39 Ljubljana 1000 - Slovenia |
London | Telecity 8-9 Harbour Exchange London E14 9GE - UK |
Madrid | TELVENT Edificio Telvent Valgrande, 6 Poligono Industrial de Alcobendas 28108 Alcobendas Madrid - Spain |
Paris | InterXion 45 Ave Victor Hugo Batiment 260 Aubervilliers Paris 93534-France |
Prague | CESNET Zikova 1905/4 PRAHA 6 Prague 160 00 - Czech Republic |
Vienna | InerXtion Louis-Häfliger-Gasse 10, Vienna 1210 - Austria |
Zagreb | SRCE Josipa Marohnica 5 Zagreb 10000 - Crotia |